Studi Perbandingan Perilaku Balok Beton Tulangan Baja Konvensional dan Balok Beton Tulangan Glass Fiber Reinforced Polymer

Authors

  • Kharisma Dwi Ramadhani Universitas Negeri Semarang, Semarang, Indonesia
  • Annisa Rahma Sabrina Universitas Negeri Semarang, Semarang, Indonesia
  • M. Vicky Restu Bachtiar Universitas Negeri Semarang, Semarang, Indonesia
  • Aviv Setiawan Universitas Negeri Semarang, Semarang, Indonesia
  • Endah Kanti Pangestuti Universitas Negeri Semarang, Semarang, Indonesia
  • Nurti Kusuma Anggraini Universitas Negeri Semarang, Semarang, Indonesia

DOI:

https://doi.org/10.53863/kst.v8i01.2107

Keywords:

Reinforced Concrete, GFRP, Flexural Strength, Deflection, Crack Pattern.

Abstract

Reinforced concrete commonly uses conventional steel reinforcement due to its good tensile strength and ductility. However, steel reinforcement is susceptible to corrosion and has a relatively high self-weight. Glass Fiber Reinforced Polymer (GFRP) has emerged as an alternative reinforcement material with high tensile strength, low weight, and excellent corrosion resistance. This study aims to compare the flexural behavior of reinforced concrete beams using GFRP reinforcement and conventional steel reinforcement in terms of maximum flexural capacity, load–deflection behavior, and crack patterns. The research was conducted experimentally through laboratory testing using the two-point loading method. The test specimens were concrete beams measuring 150 × 150 × 600 mm, reinforced with either steel or GFRP bars with diameters of 6 mm and 8 mm. The results indicate that GFRP-reinforced beams exhibit higher maximum flexural capacity than steel-reinforced beams, with increases of 44.53% for 6 mm diameter bars and 15.65% for 8 mm diameter bars. In addition, GFRP-reinforced beams show greater deflection, indicating higher flexibility compared to steel-reinforced beams. Crack pattern observations reveal that GFRP-reinforced beams develop more numerous and widely distributed cracks and tend to experience shear failure, whereas steel-reinforced beams display more controlled flexural cracking. These findings suggest that GFRP reinforcement has significant potential as an alternative to conventional steel reinforcement, particularly for structures requiring high corrosion resistance and a high strength-to-weight ratio, while careful consideration of shear failure is necessary in design

References

Abdelkarim, O. I., Ahmed, E. A., Mohamed, H. M., & Benmokrane, B. (2019). Flexural strength and serviceability evaluation of concrete beams reinforced with deformed GFRP bars. Engineering Structures, 186(December 2018), 282–296. https://doi.org/10.1016/j.engstruct.2019.02.024

Asroni, A. (2017). Teori dan Desain Balok Plat Beton Bertulang Berdasarkan SNI 2847-2013. Muhammadiyah University Press.

Elbawab, Y., Elbawab, Y., Zoughby, Z. El, & Elkadi, O. (2025). Flexural Testing of Steel- , GFRP- , BFRP- , and Hybrid Reinforced Beams. MDPI (Multidisciplinary Digital Publishing Institute).

Kosakoy, M. N. M., Wallah, S. E., & Pandaleke, R. (2017). Perbandingan nilai kuat tarik langsung dan tidak langsung pada beton yang menggunakan fly ash. 5(7), 383–392.

Kuria. (n.d.). Mengenal Kuria Bar, GFRP Rebar Inovasi Pengganti Besi Beton.

Mohammed, A. D., & Salih, O. A. (2025). AN EXPERIMENTAL STUDY ON REINFORCED CONCRETE BEAMS WITH GFRP AND ORDINARY STEEL BARS ’ FLEXURAL STRENGTH PROPERTIES. 21(1), 282–298. https://doi.org/10.2478/cee-2025-0022

Pilakoutas, K., Neoclous, K., & Guadginini, M. (2002). Design Philosophy Issues of FRP RC Structures. Journal of Composites for Construction, 6, 154–161.

Putra, M. Z. W. (2024). Dampak Buruk Overthinking Bagi Para Remaja. Al-Wasathiyah: Journal of Islamic Studies, 3(1), 29–38. https://doi.org/10.56672/alwasathiyah.v3i1.147

Soegiyono. (2017). Metode Penelitian Kuantitatif, Kualitatif dan R&D.

Sofwatillah. (2024). TEHNIK ANALISIS DATA KUANTITATIF DAN KUALITATIF DALAM PENELITIAN ILMIAH. 15(2), 79–91.

Teng, J. G., Chen, J. F., Smith, S. ., & Lam, L. (2002). FRP Strengthened RC Structures.

Badan Standarisasi Nasional. (2021). SNI 8972:2021 : Metode Uji Komposit Serat Berpolimer Sebagai Penulangan Atau Perkuatan Struktur Beton Dan Masonri.

Kosakoy M. N. M., Wallah S. E., dan Pandaleke R. (2017). Perbandingan Nilai Kuat Tarik Langsung dan Tidak Langsung Pada Beton Yang Menggunakan Fly Ash. Jurnal Sipil Statik Vol. 5 No. 7 September 2017 (383-392). ISSN: 2337-6732. Fakultas Teknik Jurusan Sipil. Universitas Sam Ratulangi Manado.

Sofwatillah, Risnita, Jailani M. S., Saksitha D. A. (2024). Tehnik Analisis Data Kuantitatif dan Kualitatif Dalam Penelitian Ilmiah. Journal Genta Mulia Vol. 15 No. 2, 2024. Universitas Islam Negeri Sulthan Thaha Saifuddin Jambi.

Published

2026-01-23

How to Cite

Ramadhani, K. D., Sabrina, A. R., Bachtiar, M. V. R., Setiawan, A., Pangestuti, E. K., & Anggraini, N. K. (2026). Studi Perbandingan Perilaku Balok Beton Tulangan Baja Konvensional dan Balok Beton Tulangan Glass Fiber Reinforced Polymer. Jurnal Kridatama Sains Dan Teknologi, 8(01), 25–40. https://doi.org/10.53863/kst.v8i01.2107

Similar Articles

1 2 > >> 

You may also start an advanced similarity search for this article.